Hello all. After lurking about the list for the past two months I thought
I'd toss out a question. I've bumped into an ASN where the vendor is
cramming carton marks for multiple cartons into a single pack level.

I'm curious, does anybody out there support a standard pack implementation
like this? My position is that each MAN segment requires its own HL***P
level but putting all the carton marks together does make for fewer
characters and I can imagine being able to support it.

...
HL*4*3*I
LIN**UA*555555001947*IT*555557
SN1**72*EA
PO4*24***CTN25
HL*5*4*P
MAN*GM*00005555550000899803 <- carton 1
MAN*GM*00005555550000899810 <- carton 2
MAN*GM*00005555550000899827 <- carton 3
HL*6*3*I
...

--
JG Motolanez