[EDI-L Mailing List Archive Home]
[Message List]
[Reply To This Message]
RE: Cleo 3780 & Sterling

Hi,
This is what ours looks like for receiving. (We use separate scripts for
sending and receiving).
MONITOR scnrecv.log
AU 9 T2 1800NNNNNNN R2
KE $$REQUEST ID=NNNNNN BATCHID='NNNNNNN'
RECEIVE /edi/data/scnin1.000
RECEIVE /edi/data/scnin2.000
PRINT /edi/data/scnrpt1.000
PRINT /edi/data/scnrpt2.000
BRANCH ON NRMEOF to 100
LOG INTRPT: DID NOT REACH NORMAL EOF .. scnin .. scnrecscr
100 VO
QU
And this for sending:
MONITOR scnout.log
AU 9 T2 1800NNNNNNN R20
KE $$ADD ID=NNNNNN BATCHID='NNNNNN' -X
BI /edi/data/outcnet/vanout.edi -T
BRANCH ON NRMEOF to 100
LOG INTRPT: DID NOT REACH NORMAL EOF .. vansnd.scr
100 VO
QU
(Obviously replace the NNNNNNN with your actual values.)
I'm sure the experts on this group can point out things to make these
better. I'm no bisync guru, just a user (set it and forget it!).
Ken Cox
Brach's Confections
-----Original Message-----
From: Alex Short [mailto:
Sent: Thursday, July 04, 2002 4:11 PM
To:
Subject: [EDI-L] Cleo 3780 & Sterling
Has anyone have much experience with using Cleo 3780 & Sterling? I'd like
to connect to them using the program, and with some retailers, they have
provided connection scripts for the various settings and login procedures
and wonder if there was one floating around for Sterling's Network.
Thanks
Alex
To unsubscribe from this group, send an email to:
Message Identifiers: <SALES>, <JOBS>,
<LIST>, <TECH>, <MISC>, <EVENT>, <OFF-TOPIC> Access the list online at:
http://groups.yahoo.com/group/EDI-L
Your use of Yahoo! Groups is subject to http://docs.yahoo.com/info/terms/
[Non-text portions of this message have been removed]
|
 |
Subscribe in XML format
| RSS 2.0 |
|
| Atom 0.3 |
|
|