[EDI-L Mailing List Archive Home]
[Message List]
[Reply To This Message]
Re: Interchange Acknowledgment - TA1 question

I ran your interchanges into the Tal Systems' Acknowledgement reporter and got
this:
07-31-2003 RECEIVED ACKNOWLEDGMENTS REPORT Page 1
15:41:39 Doctor Demento TSFA997.EXE v 1.2
Input File:C:\My Documents\ta1test.txt
File Size : 399 bytes
File Created : Thursday, July 31, 2003 8:33 PM
Last Accessed: Thursday, July 31, 2003 5:00 AM
Last Updated : Thursday, July 31, 2003 8:41 PM
Number of TA1 Interchange Acknowledgments found: 1
Number of 997 Functional Acknowledgments found: 1
----------------------------------- -----------------------------------
TA1 SENDER: 01/196938484 TA1 RECEIVER: ZZ/ALLSTATEFSS
----------------------------------- -----------------------------------
Xchange # Date Time AER Acknowledgment Code and Note
--------- -------- ----- ---
--------------------------------------------------
000003458 07/29/03 03:07 R (R) Interchange received, but rejected because
of
errors. Sender should resend.
(022) Invalid Control Structure
----------------------------------- -----------------------------------
997 SENDER: ALLSTATEFSS 997 RECEIVER: 196938484
----------------------------------- -----------------------------------
Grp Control# TS/Xmit TS/Recd TS/Acpt Group Acknowledgment
--- --------- ------- ------- ------- --------------------------------------
PO 2292 1 1 1 (A) Accepted
*** END OF REPORT ***
You already know why the TA1 was generated. What is a mystery to me is why you
got 'invalid control structure' on the 997
interchange you sent.
All I can think of is what happened to me when I cut and pasted your
interchanges: the size of the fields in the ISA segment were
incorrect due to line wrapping and automatic space filling.
(Was also wondering how you got "004010X098" as the version-release on a group
'PO' document. \004010X098 is group 'HC')
Michael Mattias
Tal Systems, Inc.
Racine WI
----- Original Message -----
From: "John Glass" <
To: <
Sent: Thursday, July 31, 2003 3:04 PM
Subject: [EDI-L] Interchange Acknowledgment - TA1 question
> I'm doing internal testing with my EAI tool (seebeyond). Problem occurred
> when sending a test 997 into the system. It spit me back out a TA1
> Interchange Acknowledgment. It's the first TA1 segment that I've ever
> seen and it shows a rejection of 997 documents sent, plus the following:
>
> 22^Invalid Control Structure
>
> Below is the 997 outbound document sent. What is the above error telling
> me is wrong with the data? Is it having a problem with the control
> number? Thanks.
>
> 997
>
> ISA*00* *00* *ZZ*ALLSTATEFSS *01*196938484
> *030729*1911*U*00401*0
>
00003458*0*T*>~GS*FA*ALLSTATEFSS*196938484*20030729*1911*3458*X*004010X098~ST*99\
7*30372~AK1
> *PO*2292~AK9*A*1*1*1~SE*4*30372~GE*1*3458~IEA*1*000003458~
>
> The returning TA1
>
> ISA*00* *00* *01*196938484 *ZZ*ALLSTATEFSS
> *030731*1513*U*00401*0
> 00000012*0*T*>
> TA1*000003458*030729*1911*R*022
> IEA*0*000000012
>
> Anybody see the problem? If you do not see a problem within the data, can
> you tell me what the error "Invalid Control Structure" is supposed to be
> referring to?
>
|
 |
Subscribe in XML format
| RSS 2.0 |
|
| Atom 0.3 |
|
|